A high-resolution imaging system designed for low energy radiation imaging (X-rays, electron and UV). The system consist of a high-resolution CCD digital CRYCAM camera and a thin YAG:Ce or LuAG:Ce single crystal scintillating screen.
Imaging System Components
- CRYCAM boxed camera head
- optical tube
- motorized focus adjusting
- objective (replaceable)
- scintillator thin screen
- scintillator holder (allows to change the screen)
- coatings – anti-reflection
- power unit,
- Peltier cooling,
- software (image acquisition and process),
Scintillator Parameters
Energy: according to scintillator type, thickness
Size: according the desired FOV
Types: see Imaging Screens page
CRYCAM Cameras
Crytur CCD cameras are devices specially developed for the imaging of objects in X-ray and electron beams with high resolution and low noise.
Cameras with Full – Frame CCD sensors
| Model | Pixel | Pixel Size | Senzor size | Image download time |
| KF - 0400 | 768 x 512 | 9 x 9 µm | 6.9 x 4.6 mm | ~ 0.6 s |
| KF- 1600 | 1536 x 1024 | 9 x 9 µm | 13.8 x 9.2 mm | ~ 2.1 s |
| KF - 3200 | 2184 x 1472 | 6.8 x 6.8 µm | 14.9 x 10.0 mm | ~ 4.8 s |
| KF - 8300 | 3358 x 2536 | 5.4 x 5.4 µm | 18.1 x 13.7 mm | ~ 12.2 s |
| KF - 01000 | 1024 x 1024 | 24 x 24 µm | 24.6 x 24.6 mm | ~ 1.4 s |
| KF - 06300 | 3072 x 2048 | 9 x 9 µm | 27.7 x 18.4 mm | ~ 8 s |
| KF - 9000 | 3072 × 3072 | 12 × 12 µm | 36,9 × 36,9 mm | ~ 12,5 s |
| KF - 16000 | 4096 × 4096 | 9 × 9 µm | 36,9 × 36,9 mm | ~ 22 s |
Acquisition time: from 0.09s up to sensor saturation.
Cameras with Interline Transfer CCD sensors
| Model | Pixel resolution | Pixel size | Sensor size | Image download time |
| KI - 2000 | 1604 x 1204 | 7.4 x 7.4 µm | 11.8 x 8.9 mm | ~ 2.6 s |
| KI - 4000 | 2056 x 206 | 7.4 x 7.4 µm | 15.2 x 15.2 mm | ~ 5.7 s |
| KI - 11000 | 4032 x 2688 | 9 x 9 µm | 36.3 x 24.2 mm | ~ 14 s |
Acquisition time: from 0.05s up to sensor saturation.

A Camera Head
Parameters:
Shutter: Yes
Binning: 1x1 to 4x4.
Reading: Two modes, standard and low-noise.
Frames accumulation: Yes.
CCD signal processing: correlated double sampling (CDS) + 16 bit A/D converter.
Image acquisition: Quick preview mode/ acquire mode.
Features: Background subtracting, Flat-field correction.
Antiblooming: SW controlled, Interline Transfer CCDs only.
Cooling: Peltier driven, >50°C below the ambient temperature
Optionally: FAN / cooling water.
Data interface: USB 2.0.
Power source: 12 VDC/ 5 A/ 100-240 V/ 50-60Hz
Imaging System Options
1. Micro-Optical system
- Optical tube with motorized focus adjusting
- Imaging area: depending on used optics
- Microscope objective 5x, 10x, 20x magnification
- Reflecting optics (to avoid direct exposing of camera to X-ray radiation)
- Scintillator: e.g. YAG:Ce screen, both sides polished, size dia. 10 x 0.02 mm glued on BK7 substrate dia. 15 x 0.3 mm
- Scintillator holder (allows to change the screen)
- Coatings – anti-reflection, optional reflection @550nm

2. Imaging system for 10 microns resolution
- Imaging area: according the CCD size and optics
- Optical tube with motorized focus adjusting
- Reflecting optics (to avoid direct exposing of camera to X-ray radiation)
- Camera objective
- Scintillator: e.g.YAG:Ce screen, both sides polished,
- size dia. 50 x 0.1 mm
- Coatings – anti-reflection, optional reflection @550nm

X-Ray Microradiography Applications
Biological and medical objects
Electronics - integrated circuit inspections
Light-weight materials with pores
X-ray, UV, synchrotron beam inspection and measurements
Highly detailed X-ray ND inspections
Composite material inspection and development
The imaging system can be used in many applications where very small details of imaged object should be observed
Features
- High radiation hardness of the imaging system
- High resolution down to 1 micron
- X-ray, electron and UV detection with the same system
- Complete system solution and supply
We are able to design and supply a complete imaging system customized to your application.
Examples

Sample: Gold Mesh (image from SEM)

The golden mesh taken by using YAG:Ce based imaging system. The golden mesh taken by using P43 phosphor screen.
Comparing the results with images taken by using standard powder phosphor imaging screens it can be seen that the resolution of YAG:Ce (LuAG:Ce) thin screens is very high.

Poppy seed
Published results can be found in the Download section: